Improvement of the test Method for the Thermal Integrity of Cast-in-place Pile Tip: Optimizing The Layout of Temperature Measuring Points
Zhiguo Ma, Chenjin Shi, Yuan Hou, Chao Xue, Minghao Sun and Yong Zeng
PowerChina Roadbridge Group CO. LTD, Beijing, China., School of Civil Engineering, Southwest Jiaotong University, Chengdu, China
Abstract: Due to the nature of underground structures, detecting defects in pile foundations is very difficult. Many methods for detecting such defects are currently in use, with various advantages and disadvantages. A new defect detection method has been proposed—thermal integrity detection. When an abnormal concrete temperature occurs, this abnormality is attributed to a defect within the concrete. When the temperature is elevated, it is attributed to bulging; when the temperature is depressed, it is attributed to necking, mud entrapment, or hollowing. Using finite element analysis can make the identification of defects quantifiable, but the study of concrete defects in pile foundations becomes complicated due to undesirable choice of temperature measurement point locations, reducing the efficiency and accuracy of finite element inverse analysis. Based on previous research, the location of temperature measurement points is optimized in this work. First, the effect of the change of reinforcement position on the concrete temperature field is studied, and it is confirmed that the change of reinforcement position affects only the location of the measurement points, not the concrete temperature field itself. Then measurement points on the concrete surface are selected for finite element inverse analysis of the pile temperature field and the results are compared with measurements in the field. The new measurement points can avoid irrelevant factors in the finite element inverse analysis of the pile foundation temperature field. The complexity of the finite element inverse analysis is greatly reduced, and the accuracy of defect location and size identification is improved.
Keywords: Thermal Integrity Testing, Pile Foundation Defect Detection, Temperature Measurement Points, Finite Element, Heat Transfer Improvement of the test Method for the Thermal Integrity of Cast-in-place Pile Tip: Optimizing The Layout of Temperature Measuring Points
DOI:https://doi.org/10.6025/tmd/2024/12/1/1-19
Full_Text   PDF 3.97 MB   Download:   28  times
References:

[1] Matsumoto, T., Kitiyodom, P., Matsui, H., Katsuzaki, Y. (2004). Monitoring of load distribution of the piles of a bridge during and after construction. Soil Found, 44(4), 109-117.
[2] Kister, G., Winter, D., Gebremichael, Y. M. (2007). Methodology and integrity monitoring of foundation concrete piles using Bragg grating optical fibre sensors. Eng Struct, 29(9), 2048–2055.
[3] Mullins, G. (2010). Thermal integrity profiling of drilled shafts. J Deep Found Inst, 4(2), 54–64.
[4] Liu, Y. L., Xiao, H. L., Hu, Q. Z., Ma, Q., Li, L. H. (2017). Research on Integrity Detection Method for Bored Pile Using Distributed Optical Fiber Temperature Sensing Technology. Journal of Yangtze River Scientific Research Institute, 34(6), 124–127.
[5] Liu, Y.L., Huang, S.L., Xiao, H.L., Chen, W.Z., Ma. Q. (2019). Research on optimization of optical fiber layout for DTS detection of bored pile integrity. China Journal of Rock Mechanics and Engineering, 38(S2), 3841–3848.
[6] Liu, Y.L., Ding, H., Wang, K.B., Xiao, H.L., Li, L.H. (2020). Thermal conduction characteristics of DTS when detecting the integrity of cast-in-place piles considering their environment. Heat and Mass Transfer, 56(5), 2185-2202.
[7] Chen, Z., Sun, Y., Liu, Y.L., H.L. Xiao., L.G. Zhang. (2020). Study on temperature field characteristics of heat source in necking cast-in-place pile based on ANSYS. China Sciential and Technical thesis, 15(10), 1169-1176.
[8] Chunge, M. (2014). Monitoring the integrity of bored concrete piles using distributed fibre optic sensors. MPhil thesis, University of Cambridge, Cambridge.
[9] Andrew, Z., Boeckmann, J., Erik, Loehr. (2019). Evaluation of Thermal Integrity Profiling and Crosshole Sonic Logging for Drilled Shafts with Concrete Defects. Transportation Research Record, 2673(8), 86-98.
[10] Sun, Q. C., Elshafie, M., Barker, C., Fisher, A., Schooling, J., Rui, Y. (2021). Thermal integrity testing of cast in situ piles: An alternative interpretation approach. Structural Health Monitoring, 20(5), 2493-2512.
[11] Sun, Qianchen., Elshafie, M, Z.E.B., Barker, C., Fisher, A., Schooling, J., Rui, Y. (2022). Integrity monitoring of cast in-situ piles using thermal approach: A field case study. Engineering Structures, 272, 1-16.
[12] Mullins, G., Johnson, KR. (2016). Optimizing the use of the thermal integrity system for evaluating auger-cast piles. Final report, FDOT-BDV35-977-09, Tallahassee, FL: Department of Transportation.
[13]ASTM D7949-14. Standard Test Methods for Thermal Integrity Profiling of Concrete Deep Foundations.
[14] Zhu, Bofang. (2003). Temperature Stress and Temperature Control of Mass Concrete. Beijing: China Electric Power Press.
[15] Zhang, J. R., Liu, Z. Q. (2006). A study on the convective heat transfer coefficient of concrete in wind tunnel experiment. China Civil Engineering Journal, 39(9), 39-42+61.
[16] Rui, Y., Kechavarzi, C.-O., Leary, F., Barker, C., Nicholson, D., Soga, K. (2017). Integrity testing of pile cover using distributed fiber optic sensing. Sensors, 17(12).
[17] De, Schutter, G., Taerwe, L. (1995) General hydration model for Portland cement and blast furnace slag cement. Cement Concrete Research, 25(3), 593–604.
[18] Zhu, Bofang. (2009). New progress of concrete dam theory and technology. Beijing: China Water Resources and Hydropower Publishing House, 2009.
[19] Schindler, K., Folliard, J. (2005). Heat of Hydration Models for Cementitious Materials. ACI Materials Journal, 102(1), 24-33.
[20] Xue, S. D., Kang, G. B., Li, X. Y., Gen, Y., Li, J. G., Song, Y. J. (2020). Hydration Temperature Field of Large-size Concrete Member During Hardened Period. Journal of Beijing University of Technology, 46(2), 147-153.
[21] Ma, Chao. (2020). Temperature field of mass concrete based on BP neural network positive and negative analysis research. MPhil thesis, Changsha University of Science & Technology, Changsha.


Home | Aim & Scope | Editorial Board | Author Guidelines | Publisher | Subscription | Previous Issue | Contact Us |Upcoming Conferences|Sample Issues|Library Recommendation Form|

 

Copyright 2011 dline.info