Programmable Logic Operation for the Generalized Subtraction Procedures
Tsvetan Shoshkov1 and Georgy Mihov1
Faculty of Electronic Engineering and Technologies at Technical University of Sofia 8, St. Kl. Ohridsky Blvd, 1000 Sofia, Bulgaria., Faculty of Electronic Engineering and Technologies at Technical University of Sofia 8, St. Kl. Ohridsky Blvd, 1000 Sofia,
Abstract: We have deployed the programmable logic operation to develop the generalized subtraction procedure for the suppression baseline drift. We have used the Matlab environment to test it. Besides, we have used the VHDL for implementing programmable logic. The logic structure in FPGA is used for programming. The efficiency of the proposition depends how best the algorithms created can help the real-time execution in natural sequences. The developed real-time algorithm can remove the baseline drift in the ECG sample and ends. This research will serve as a model for the future developments in the subtraction procedures.
Keywords: ECG, Drift, Drift Removing, Subtraction Procedure Programmable Logic Operation for the Generalized Subtraction Procedures
DOI:https://doi.org/10.6025/jet/2023/14/1/9-16
Full_Text   PDF 2.33 MB   Download:   92  times
References:

[1] Mihov, G. & Dotsinsky, I. (2010) Subtraction procedure for removing the baseline drift from ECG signals. Annual Journal of Electronics, 118–122.
[2] Mihov, G., Dotsinsky, I., Levkov, C. & Ivanov, R. (2008) Generalised equations and algorithm of the subtraction procedure for removing power-line interference from ECG. In: Proceedings of the Technical University of Sofia, Vol. 58, pp. 31–38, b. 2, Sofia,.
[3] Mihov, G., Dotsinsky, I.V. & Georgieva, T.S. (2005) Subtraction procedure for powerline interference removing from ECG: Improvement for non-multiple sampling. Journal of Medical Engineering and Technology, 29, 238–243 [DOI: 10.1080/ 03091900412331280897] [PubMed: 16126585].
[4] Levkov, Ch., Mihov, G., Ivanov, R., Daskalov, I.K., Christov, I. & Dotsinsky, I. (2005) Removal of power-line interference from the ECG: A review of the subtraction procedure. BioMedical Engineering OnLine, 4, 50 [DOI: 10.1186/1475-925X-4-50] [PubMed: 16117827].
[5] Mihov, S., Ivanov, R. & Popov, A. (2008) “Real-Time Subtraction Procedure for Eliminating Power-Line Interference from ECG”, ET2008. Sozopol, 55–60, b. 1.


Home | Aim & Scope | Editorial Board | Author Guidelines | Publisher | Subscription | Previous Issue | Contact Us |Upcoming Conferences|Sample Issues|Library Recommendation Form|

 